===== Popads =====
 
Login: Password:  Do not remember me

Categories




Get Premium:
Rapidgator




Tags






Software / Graphics & DesignMerrick MARS 2019.2 (x64)



Merrick MARS  2019.2 (x64)

Merrick MARS 2019.2 (x64) | 718.2 mb

Merrick & Company, a global leader in light detection and ranging (LiDAR), digital orthophotography, hyperspectral imaging, and geographic information systems (GIS) data integration, is pleased to announce the release of Version 2019.2 of the Merrick Advanced Remote Sensing (MARS) software suite.

Merrick MARS 2019.2 - Release Date: May 21, 2019

Enhancements:

Revised value gradationsimplemented for two QC Module tests
The color gradations (and their associated values) for relative vertical accuracy have been modified in test DC8 of the 'LiDARWorkflow QC -1 LiDAR Data Checks' and test CC2 of the 'LiDAR Workflow QC -2 LiDAR Calibration Checks' tools. The increment has been reduced from 3 cm to 2 cm to better depict areas of possible concernas lidar sensors' accuracy has improved.
Modifications to Class Descriptions made to reflect recent changes to the LAS v1.4 specification
To keep in compliance with the recent revision to the LAS Specification 1.4 -R14(ASPRS; March 26, 2019), several class descriptions have been updated: Class 19 is now described as 'Overhead Structure', Class 20 is now 'Ignored Ground', Class 21 is now 'Snow', and Class 22 is now 'Temporal Exclusion'. In addition, tools that use anyof these newly-described classes have been modified accordingly -for example, 'Breakline Properties' and 'Reassess Points for Ignored Ground Classification' on the 'Breaklines' tab.
Search Radius option added to 'Reference Reclass' tool to improve performance
An option to set a Search Radius (in project units) has been added to the 'Reference Reclass' tool to improve performance when determining candidate pointsusing the selected criteria
Installation folder reconfiguration allows users without Admin rights to open MARS
Because of stricter security protocols in Windows 10 compared to earlier versions, users with basic user accounts (i.e., those lacking any Administrator rights) may have had issues opening and/or using previous versions of MARS. Beginning with this version, the 'Log' folder that is used for troubleshooting will be moved from the install path to the temporary folder ('.mars') path.Previous default location: C:\MARS\LogNew default location: C:\Users\\.mars\LogThis ensures that MARS will have write and modify access to the 'Log' folder for all users.

List of Bug Fixes:

- Bug fixedcausing a program hang when exporting contours (shapefile) with specific 'Line Cleanup' settings.
- Bug fixed in 'System Information' tool causing the wrong Operating System namesto be reported for Windows 10 and Windows Server 2016.
- Bug fixed causing 'Edit Collection Scan Display' interface to show old collection scan numbers after a 'Collection Scan Renumbering' operation has been performedon Riegl sensor data.
- Bug fixed in 'Reference Reclass' tool that was causing a failure when the input Classified files contained a very large number of points.

Merrick MARS  2019.2 (x64)


About Merrick MARS. MARS is a robust, production-grade Windows application designed tomanage, visualize, process and analyze LiDAR data. Boasting powerful visualization capabilities andunparalleled performance, MARS is ready to support your LiDAR data processing needs.

About Merrick & Company. Merrick & Company, an engineering, architecture, and geospatial solutions firm, serves domestic and international clients in the energy and chemicals, national security, life sciences, and infrastructure markets. The employee-owned company maintains 20 offices in the United States, Canada, Mexico, and the United Kingdom.

Product: Merrick MARS
Version: 2019.2 build 8403
Supported Architectures: x64
Website Home Page :
http://www.merrick.com

Language: english
System Requirements: PC *
Supported Operating Systems: *
Size: 718.2 mb
Minimum System Requirements
- Microsoft Windows 7 (64-bit) w/ SP1, Server 2008 R2 (64-bit), or a later 64-bit version of Windows(both physical and virtual machines are supported)
- Microsoft .NET Framework 4.6.2 (typically present with the above operating systems, otherwise available free from Microsoft's download site)
- 1.5GHz 64-bit (x64) Processor
- 4GB RAM
- 10 GB available hard disk space
- SXGA(1280x 1024) or higher-resolution graphicsadapter/monitor; 256MB of graphics memory(NOTE: nVidia graphics adapter required for complete visual results with the QC Module)
- Internet Connection(to use WMS imageryand Google Earth1following)
- USB 2.0 (or later) portif using a USB hardware key (dongle) for licensing
- Keyboardand2-button mouse or compatible pointing device

Recommended System Configuration

- 2.0GHz or faster 64-bit (x64) multi-core Processor; Intel Core i7 or equivalent Processor preferredwith at least four discrete cores (or two hyper-threaded cores)
- 12GB or more RAM
- SXGA(1280 x 1024) or higher-resolution graphicsadapter/monitor; nVidia graphics adapter with at least 512 MB of graphics memory.(NOTE: nVidia graphics adapter required for complete visual results with the QC Module)
- Internet Connection(to use WMS imagery, Google Earth1following,and interpret some results in the QC Module)
- USB 2.0 (or later) portif using a USB hardware key (dongle) for licensing
- Keyboard and2-button mouse with scroll wheel or compatible pointing device

Download link:



Links are Interchangeable - No Password - Single Extraction


[related-news]

Related News

    {related-news}
[/related-news]

Comments (0)

Ooops, Error!

Information

Users of Guests are not allowed to comment this publication.

Search



Updates




Friend Sites


TinyDL
WarezOmen :: ArchivX.to | Handverlesene Datenbank!


Your Link Here ?
(Pagerank 4 or above)


FaceBook Suport